SPD Surge Protector Protective Device AC 40kA 1P 270V 385V 440V Surge Arrester

AC Series modular surge protector(SPD) for use in thundermoviesNoise or other transient overvoltage caused bythe surge to protect the power line.

https://www.ppspd.com/spd-surge-protector-protective-device-ac-40ka-1p-270v-385v-440v-surge-arrester.html

AC Series modular surge protector(SPD) for use in thundermoviesNoise or other transient overvoltage caused by the  surge  to  protect  the power line.The  surge currenti s discharged  to the earth to limit  the overvoltage. The main installation In  the   power supply  system  of  each  distributioncabinet(box),to   protect  the   lines  and  electrical equipmentAnd the role of personal safety.

Technical data

Model

CYD1

SPD according to EN 61643-31 / IEC 61643-31

Type2 / class II

UC( AC)

275V 、320V 、380V 、420V 、440V

Nominal discharge current (8/20 μs) In

10kV

20kV

30kV

40kV

60kV

Maximum discharge current (8/20 μs) Imax

20kV

40kV

60kV

80kV

100kV

Voltage protection level Up

1.2kV

1.5kV

2.0kV

2.2kV

2.5kV

Response time tA

25 ns (L-N)

Residual current a.c. and d.c.    IPE

0.3 mA(DC), 0.3 mA(AC),

Humidity range

5% … 95%

Range of operating temperatures TU

-40°C … +70°C

Atmospheric pressure and altitude

80k Pa … 106k Pa,

-500 m … 2000 m

Operating state / fault indication

Green ok / Red defect

Number of ports

One port

Cross-sectional area (max.)

2 AWG (Solid, Stranded) / 4 AWG (Flexible)

35 mm2 (Solid, Stranded) / 25 mm2 (Flexible)

For mounting on

35 mm DIN rail acc. to EN 60715

Enclosure material

V0 fireproof material

Place of installation

indoor installation

Degree of protection

IP 20

Poles

1P、 2P、 3P、 4P、3P+N、1P+N

Remote Contact Signaling

Type of remote signalling contact

C+NC: Normally closed C+NO: Normally open

C: Common contact

a.c. switching capacity

250V / 0.5 A

d.c. switching capacity

250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A

Cross-sectional area for remote signalling terminals

max. 1.5 mm2 solid / flexible

Remote signalling alarming mode

Normal: closed;

failure: open-circuit

Acessibility

Inaccessible

Protection fuction

Overcurrent

PV earthing system

Earthed and Unearthed (both)

SPD failure mode (OCFM/SCFM)

OCFM

Circuit diagram

Drawings

4P:72MM*90MM*62MM

4P:108MM*90MM*62MM

4P:144MM*90MM*62MM

Installation, Usage and Maintenance

This product can only be installed and maintained by qualified professionals. The installation position cannot be touched by hands. Ensure that it is unpowered and check whether the SPD is all right before installation. If there’s damage or the display window is red, the SPD cannot be used any more; if the window is green, the SPD is normal.

The installation of SPD should be based on Fig. 3    IEC 60364-5-53. The cross-sectional area of ground wire should not be less than 4 mm2, and the length of total lead not more than 0.5m.

The minimum distance from any earthed conductive surface at which the SPD can be installed is 8mm.

Connection of remote  signalling  alarm: the  SPD  is  provided  with  remote  signalling  interfaces  (NC,  COM  and  NO, normally closed), applicable for remote centralized monitoring or alarm.

After the connection, check if the module is fitted in. If so, NC and COM are closed; if not, repress the module.

Installation Diagram

Reviews

There are no reviews yet.

Be the first to review “SPD Surge Protector Protective Device AC 40kA 1P 270V 385V 440V Surge Arrester”